04 / 09 Electrical services
Electrical Maintenance Services
Electrical installations wear out quietly: cables age, connections loosen and circuits get altered, often unnoticed until something trips or scorches. Electrical maintenance finds those problems first. Our electrical inspection and testing covers homeowners, landlords and businesses: Electrical Installation Condition Reports (EICRs), PAT testing, planned electrical maintenance programmes, and the remedial work a report calls for.
Electrical maintenance is part of our electrician services. For new circuits, rewires and consumer units, see our domestic electrical installation service.
- Part ofElectrician Services
- On this page10 topics covered
- Answered here6 common questions
- FreeSurvey & itemised quote
01EICR
What Is an EICR?
An Electrical Installation Condition Report is a formal report on the condition of an existing electrical installation, carried out against BS 7671, the UK wiring regulations. It is sometimes called a periodic inspection. It tells you whether the installation is safe to keep using, and what needs attention.
An inspection usually includes:
- A visual inspection of the consumer unit, wiring and accessories, looking for damage, overheating and unsafe alterations.
- Earthing and bonding checks: The main earth, and the protective bonding to incoming gas and water pipes.
- Testing: Continuity of protective conductors, insulation resistance, polarity, earth fault loop impedance and the operation of RCDs.
- An agreed extent and limitations: What was and was not inspected, written into the report.
The power is off for parts of the testing, so we agree the timing with you, and with tenants or staff, in advance.
02Codes
What Do the EICR Codes Mean?
Each problem found is given a code, and the codes decide the overall result:
| Code | Meaning | What happens next |
|---|---|---|
| C1 | Danger present. Risk of injury | Made safe straight away, usually by isolating the circuit or equipment, with your agreement |
| C2 | Potentially dangerous | Urgent remedial work needed |
| C3 | Improvement recommended | Not a failure on its own; worth planning in |
| FI | Further investigation required without delay | A possible problem the inspection could not confirm, which must be investigated |
Any C1, C2 or FI makes the report unsatisfactory. A report with only C3 observations, or none at all, is satisfactory. Common findings in older homes include missing RCD protection, missing bonding, old rubber-insulated cables and DIY alterations.
03Frequency
How Often Should an Electrical Installation Be Inspected?
Each report recommends a date for the next inspection. As general guidance:
- Rented homes in England: At least every five years, by law (see below), and earlier if the last report says so.
- Owner-occupied homes: Commonly recommended around every ten years, and when you buy a home.
- Before buying or selling: Not a legal requirement for a sale, but it tells a buyer what they are taking on.
- Business premises: Usually more often than homes; see our commercial electrical installation page.
04Landlords
Do Landlords Need an EICR?
Yes. Under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, private landlords in England must:
- Have the installation inspected and tested by a qualified and competent person at least every five years.
- Give a copy of the report to existing tenants within 28 days of the inspection, to new tenants before they move in, and to a prospective tenant within 28 days if they ask for it.
- Give a copy to the local authority within 7 days if it asks for one.
- Carry out remedial or further investigation work within 28 days, or sooner if the report says so, and give written confirmation that it has been done to the tenants and the local authority within 28 days of completion.
- Keep a copy of the report to give to the person carrying out the next inspection.
Councils can impose financial penalties on landlords who do not comply. Smoke and carbon monoxide alarm duties are separate; see our fire alarm installation and maintenance service. We work with letting agents to arrange access with tenants.
05PAT testing
PAT Testing
Portable appliance testing checks equipment that plugs in: kettles, heaters, extension leads, computers and power tools. It involves a visual inspection of the plug, cable and casing and, depending on the item, tests of earth continuity and insulation. Items that pass are labelled and recorded; failures are taken out of use.
There is no fixed legal interval for PAT testing. Employers must keep electrical equipment safe under the Electricity at Work Regulations 1989, and landlords must make sure appliances they supply are safe. PAT testing, with records, is a common way of showing that. How often depends on the equipment and how it is used: a site power tool needs checking far more often than an office lamp.
06Planned maintenance
What Is Planned Preventive Maintenance?
Planned preventive maintenance means inspecting and servicing electrical systems on a schedule, so faults are found before they cause a breakdown or a failed inspection. For businesses and landlords with several properties, an electrical maintenance contract can include:
- Periodic inspection and testing: (EICRs) at the intervals the reports recommend.
- PAT testing of portable equipment, with records.
- Emergency lighting checks: Typically a short monthly functional test and an annual full-duration test, recorded in a logbook.
- Distribution board checks: For overheating and loose connections, with thermal imaging where useful.
- Fire alarm servicing through our fire alarm installation and maintenance service.
- A maintenance log for insurers, landlords and fire safety inspectors.
As electrical maintenance contractors, we agree the schedule and scope before the contract starts, and plan visits around your opening hours.
07Remedial work
Remedial Work After an EICR
An unsatisfactory report is a list of jobs. We explain each observation, price the remedial work in writing, and carry it out:
- Small repairs, such as damaged accessories or polarity faults, through our electrical repair services.
- Adding RCD protection and upgrading main protective bonding.
- Consumer unit replacements and new circuits, which are notifiable and are certified through one of the routes the building regulations allow.
- Rewiring, where old cables fail insulation tests, through our domestic electrical installation service.
When the work is complete, you receive the right certificate and written confirmation for your tenants and the local authority. We can also quote for the remedial work on another electrician's report. If a C1 danger is found or reported to you and cannot wait, see our emergency electrical services.
08Cost
How Much Does Electrical Maintenance Cost?
An EICR for a home can usually be given a fixed price in advance. The main factors are:
Every factor is priced line by line after your free survey — no guesswork, staged payments.
Book an EICR- 01
The size of the property and the number of circuits.
- 02
The age and condition of the installation, and access to it.
- 03
For PAT testing
The number and type of items.
- 04
For maintenance contracts
The number of sites, what is included and how often.
We give you a written quote before we start. Remedial work is quoted separately, after you have the report.
09Areas
Electrical Maintenance Across London
We carry out electrical maintenance across London, with a focus on east and south-east London. Find out more on our pages for electrical maintenance services in London, electrical maintenance services in Ilford, electrical maintenance services in Barking, electrical maintenance services in Dagenham, electrical maintenance services in East Ham and electrical maintenance services in Orpington.
10FAQs
Electrical Maintenance FAQs
What is an EICR?
A formal inspection and test of an existing electrical installation against BS 7671. It codes any problems and says whether the installation is satisfactory.
Do landlords need an EICR?
Yes. Private landlords in England must have the installation inspected and tested at least every five years, give the report to tenants, and complete required remedial work within 28 days or sooner.
How often should an electrical installation be inspected?
Rented homes at least every five years; owner-occupied homes commonly around every ten years and when buying. The report also gives a recommended date for the next inspection.
What is planned preventive maintenance?
Inspecting, testing and servicing electrical systems on a set schedule, so faults are found before they cause breakdowns, with records kept for insurers.
What is the difference between C1, C2 and C3?
C1 means danger is present and is made safe immediately, C2 means potentially dangerous and needs urgent remedial work, and C3 is a recommended improvement. Any C1, C2 or FI makes the report unsatisfactory.
Is PAT testing a legal requirement?
No law sets a fixed interval, but employers and landlords must keep the equipment they provide safe. PAT testing with records is a common way of showing that.
12Electrician Services
Explore other electrical services
Next step
Book an Electrical Inspection
Tell us about the property and when it was last inspected. We will send you a written quote for the EICR, PAT testing or maintenance plan you need.
Send us your last report on WhatsApp to get started, or use our contact form.
- Free survey
- Itemised written quote
- One project manager