07 / 09 Electrical services

Fire Alarm Installation and Maintenance

A fire alarm only protects people if it is the right system, in the right places, and still working. Our fire alarm installation service covers smoke alarm installation in homes and rented properties, interlinked systems for new builds, extensions, loft conversions and HMOs, and fire alarm systems for shops, offices and other commercial premises. We also provide fire alarm maintenance and fire alarm servicing.

Fire alarm installation and maintenance is part of our electrician services.

Fire Alarm Installation and Maintenance
  • Part ofElectrician Services
  • Our process4 clear steps
  • Answered here6 common questions
  • FreeSurvey & itemised quote

01Which system

What Fire Alarm System Do I Need?

BuildingTypical systemWhat sets the rule
Your own homeMains-powered, interlinked smoke and heat alarmsRecommended; required when you build, extend or convert
Rented homeAt least a smoke alarm on every storey, and CO alarms where neededLandlord regulations (2022)
New home, extension or loft conversionMains-powered, interlinked alarms with battery backupBuilding regulations (Approved Document B)
HMOInterlinked alarms, or a panel system in larger HMOsCouncil licensing and fire safety guidance
Shop, office or commercial unitA fire alarm system with a control panelFire risk assessment, under the Fire Safety Order

We survey the property and recommend the system that meets the rules that apply.

02Homes

Smoke Alarm Installation for Homes

  • Interlinked alarms: When one alarm detects fire, they all sound, so you hear it wherever you are in the house.
  • Mains-powered with battery backup: So they keep working in a power cut.
  • Radio-interlinked alarms: Alarms that link wirelessly, avoiding cables between them in a finished home.
  • The right detector in each room: Optical smoke alarms in hallways, landings and living rooms; heat alarms in kitchens, where smoke alarms give false alarms; and carbon monoxide alarms in rooms with a boiler, gas fire or wood burner.

Alarms have a replace-by date printed on them. Any new circuit is certified through one of the routes the building regulations allow, through our domestic electrical installation service.

03Landlords

Smoke and CO Alarms for Landlords

Since 1 October 2022, private and social landlords in England must:

  • fit at least one smoke alarm on every storey with a room used as living accommodation;
  • fit a carbon monoxide alarm in any room used as living accommodation with a fixed combustion appliance, such as a boiler or wood burner (gas cookers are excluded);
  • repair or replace an alarm once they are told it is faulty.

Private landlords must also check the alarms are working on the first day of each new tenancy. The rules do not require a particular type of alarm. Landlords also need an EICR at least every five years through our electrical maintenance services, and a yearly landlord gas safety certificate.

04Building regulations

New Homes, Extensions and Loft Conversions

Approved Document B, the fire safety guidance to the building regulations, calls for mains-powered, interlinked alarms with battery backup in new homes, designed to BS 5839-6. For most houses, the minimum is a Grade D2, Category LD3 system:

  • Grade D1 or D2: Mains-powered alarms with a sealed (D1) or replaceable (D2) backup battery.
  • Category LD3: Alarms on the escape route, such as hallways and landings.
  • Category LD2 or LD1: Extra alarms in rooms where a fire is more likely to start, such as kitchens and living rooms, or in all such rooms.

When you add a new storey with a loft conversion, or new rooms with a house extension, the alarms usually need to be extended so the whole escape route is covered on every storey.

05HMOs

Do HMOs Need Interlinked Fire Alarms?

Yes, in almost all cases. Councils set fire safety standards for houses in multiple occupation through licensing conditions and inspections, often based on national fire safety guidance for housing. A small shared house usually needs mains-powered, interlinked alarms on the escape route, with extra detectors in rooms such as the kitchen and, often, bedrooms. Larger HMOs, bedsits and buildings converted into flats may need a Grade A system with a control panel, plus emergency lighting. The shared parts of an HMO also come under the Fire Safety Order, so a fire risk assessment is needed. Check your licence conditions before work starts, and we design the system to meet them.

06Commercial

Commercial Fire Alarm Systems

Under the Regulatory Reform (Fire Safety) Order 2005, the "responsible person" for non-domestic premises must carry out a fire risk assessment, which sets out the fire detection and warning the building needs. Commercial systems are designed, installed and serviced to BS 5839-1, which uses categories:

  • Category M: Manual call points only, at exits and on escape routes.
  • Category L (L1 to L5): Automatic detection to protect life, from the whole building (L1) down to escape routes (L4) or specific risks (L5).
  • Category P (P1 and P2): Automatic detection to protect the building and its contents.

A system can be conventional, where the panel shows the zone, or addressable, where it shows the exact device. Emergency lighting to BS 5266-1 is covered by our commercial electrical installation service, and fit-outs by our commercial construction service.

07BS 5839

What Is BS 5839?

BS 5839 is the British Standard code of practice for fire detection and fire alarm systems. Part 1 covers non-domestic premises and Part 6 covers homes, including HMOs. It sets out how systems are designed, installed, commissioned and maintained, and the records to keep.

08Maintenance

How Often Should Fire Alarms Be Serviced?

  • Homes: Press the test button at least once a month, keep alarms free of dust, and replace them by the date printed on them.
  • Commercial systems: BS 5839-1 recommends a weekly test from a different call point each week, carried out by the responsible person, and inspection and servicing by a competent person, commonly every six months. Results go in the logbook.

Our maintenance visits test detectors, call points and sounders, check the panel and standby batteries, and record the results. Repeated false alarms are investigated and put right.

09Cost

How Much Does Fire Alarm Installation Cost?

Every job is priced after a survey, with a written quote. The main factors are:

Your quote, itemised

Every factor is priced line by line after your free survey — no guesswork, staged payments.

Get a free quote
  1. 01

    The size and layout of the building and the number of storeys.

  2. 02

    The system

    Interlinked alarms, a radio-interlinked system, or a panel system.

  3. 03

    The category required by building regulations, your licence or your fire risk assessment.

  4. 04

    Cabling

    Whether cables can be run easily or the property is finished.

  5. 05

    For servicing

    The number of devices and the frequency of visits.

10Process

How It Works

Planned before we start, managed by one project manager, signed off at the end.

  1. 01

    Survey

    We look at the building, its use, and any licence conditions or fire risk assessment.

  2. 02

    Design and quote

    We recommend the system and give you a written quote.

  3. 03

    Install and commission

    The system is installed, every device tested, and you receive the certificates.

  4. 04

    Maintain

    We can arrange regular servicing and keep the records.

12FAQs

Fire Alarm FAQs

Ask a different question
Q01

What fire alarm system do I need?

It depends on the building: interlinked mains alarms for most homes, at least a smoke alarm on every storey for rented homes, and a panel system for most commercial premises.

Q02

How often should fire alarms be serviced?

Test home alarms monthly. For commercial systems, BS 5839-1 recommends weekly call point tests and servicing by a competent person, commonly every six months.

Q03

Do HMOs need interlinked fire alarms?

Yes, in almost all cases. The council's licence conditions set the system, and larger HMOs may need a panel-based Grade A system.

Q04

What is BS 5839?

The British Standard code of practice for fire alarm systems: Part 1 for non-domestic buildings and Part 6 for homes. It covers design, installation, commissioning and maintenance.

Q05

Do landlords have to fit carbon monoxide alarms?

Yes, in England, in any room used as living accommodation with a fixed combustion appliance such as a boiler or wood burner. Gas cookers are excluded.

Q06

Can smoke alarms be interlinked without new wiring?

Yes. Radio-interlinked alarms link wirelessly, so cables do not need to run between them, which suits finished homes.

Next step

Get a Free Fire Alarm Quote

Tell us about the property, who lives or works there, and any licence conditions or fire risk assessment. We will arrange a survey and send you a written quote.

Send us photos on WhatsApp to get started, or use our contact form.

Fire Alarm Installation and Maintenance — finished project
  • Free survey
  • Itemised written quote
  • One project manager